Motion test with EGIL200
Learn how to set up the EGIL200 for testing a motion measurement. This application note includes transducer example for relative measurement with common mechanism, with both analogue and digital types.
Objavljeno: 15 jun 2023
Preuzimanje PDF-a
Directional earth-fault protection - SVERKER 900
The fault current is set to 80mA tosimulatethe high current generated at the intermittent earth fault. The zero voltage is set to 20V;theconfiguration ismade in13 states.The fault states and the first two memory states are set to 20ms. The memory states havetimesselected togetthetrip as close to set time 1,2s as possible. In generator configuration,set U4gen to aux voltage DC.Set “Advanced mode” in SVERKER configuration.
Objavljeno: 28 april 2022
Preuzimanje PDF-a
Case study: NB DFR on HV CVTs
Reducing the risk of failure on high voltage instrument transformers in the transmission system using the application of narrowband dielectric frequency response (NB DFR) on HV CVTs.
Objavljeno: 10 mart 2021
Preuzimanje PDF-a
Measuring cable impedance with SVERKER900
This is an easy solution to measure the impedance values for cables, the values are used for calculation of compensation factor in distance protection.The compensation factor is first theoretically calculated and these values can now be compared with the measured values.
Objavljeno: 14 decembar 2020
Preuzimanje PDF-a
Preventive maintenance of rolling stock
The test and maintenance of electrical components on rolling stock is not an easy job to do. Some maintainers dismount some of the parts and bring them to a central location for revision and maintenance. This is a cumbersome and time consuming exercise. In many cases, the electrical parts are replaced only when they break down and are not subject to periodical testing. This of course holds a risk as some parts, e.g. circuit breakers, are crucial for safety reasons.
Objavljeno: 3 novembar 2020
Preuzimanje PDF-a
Case Study on IDAX300 and VAX020
The Power Grid Corporation of India Limited (PGCIL) is an Indian state-owned company headquartered in Gurugram (North India) engaged mainly in Trans-mission of Power and transmits about 50% of the total power generated in India on its transmission network. The company owns and operates about 1,61,790 circuit kms of transmission lines at 800/765 kV, 400 kV, 220 kV & 132 kV EHVAC and +500 kV HVDC levels and 248 sub-stations. Also, it has the transformation capacity of about 396 825 MVA as of 30th November 2019.
Objavljeno: 26 avgust 2020
Preuzimanje PDF-a
DLRO2: long test lead test mode
When measuring very low resistance the four-wire test method has for many years been the standard method. The main advantage being that it simply and easily removes the resistance of the test leads from the measurement. However, what happens when those test leads need to be verylong?
Objavljeno: 27 jul 2020
Preuzimanje PDF-a